Steam Generators
Steam generators are wall-mounted machines which generate and dispense steam into steam rooms, steam showers, steam cabins or on a larger scale hammams/rasuls. These generators are also very effective for curing wood, and maintaining high humidity levels in enclosed areas.
Scandi Spa is a manufacturer, supplier and installer of steam generator units locally and internationally. Our generators can be packaged for DIY installations which include detailed manuals. Installation can easily be completed by your builder or handyman.
Steam generators are available in various powers which are suitable according to the area size serviced:
Steam Generator Model (kW) |
Area Serviced (m3) |
Size of Unit (mm) |
6kW | 4m3 | 600x250x300mm |
7kW | 5m3 | 600x350x700mm |
9kW | 6m3 | |
12kW | 8m3 | |
15kW | 10m3 | 600x500x700mm |
18kW (Industrial strength) |
14m3 |
Single Phase Circuit Breaker Requirement (AMP) |
Single Phase Cable Type (mm) |
30amps | 4mm |
35amps | 6mm |
45amps | 6mm |
NOT AVAILABLE FOR SINGLE PHASE | |
NOT AVAILABLE FOR SINGLE PHASE | |
NOT AVAILABLE FOR SINGLE PHASE . |
Three Phase Circuit Breaker Requirement (AMP) |
Three Phase Cable Type (mm) |
10amps per phase | 1.5mm 4/core |
15amps per phase | 2.5mm 4/core |
15amps per phase | 2.5mm 4/core |
20amps per phase | 4.0mm 4/core |
25amps per phase | 6.0mm 4/core |
30amps per phase . |
6.0mm 4/core |
Scandi Steam Generators include: Digital temperature controller, temperature sensor and holder, on/off switch and one or two steam nozzles (depending on machine size)
* The digital temperature controller is mounted on the steam unit.
* The on/off switch is low voltage for safety and waterproof which allows it to be installed in the shower or bathroom.
Steam Generator Specifications
- Stainless steel internal tank, robust water level float device, electromechanical water filling, low level cut-out, safety fuse for protection switches,
- low voltage supply to control box, insulation, relays, 15mm drain valve, 22mm steam outlet. Digital temperature control and display.
- The unit should be mounted under cover if possible, or have a weatherproof cover to protect it from the elements.